Abend: Double Fault Processor Exception during in-place upgrade.
(Last modified: 13Nov2002)
This document (10068669) is provided subject to the disclaimer at the end of this document.
fact
Novell NetWare 6.0
In-place upgrade
symptom
Abend: Double Fault Processor Exception during in-place upgrade.
Running Process is HDetect Proc
cause
The server registry files had become corrupt.
fix
Delete the server registry files (SERVCFG.000, SERVCFG.NBK, SERVCFG.TMP) from the default DOS directory (usually C:\NWSERVER) and start the installation again.
For additional information on NetWare 6, please see the following solution. TID #10064501 - NetWare 6 Readme Addendum