Abend: page fault processor execption in timesync.nlm

(Last modified: 30Oct2002)

This document (10067055) is provided subject to the disclaimer at the end of this document.

fact

Novell NetWare 6.0

Server Abends

Timesynce.nlm v6.01a September 17 2001

symptom

Abend: page fault processor execption in timesync.nlm

cause

If DNS (NAMED) is not running, TIMESYNC.NLM will abend if it cannot resolve the DNS name in the Timesources list.

Configured timesources are...

ntp2a.mcc.ac.uk:123, ntp2b.mcc.ac.uk:123, ntp2c.mcc.ac.uk:123, ntp2d.mcc.ac.uk:123

fix

If NAMED is running then timesync loads with no problem.  If both Secondary and Primary servers are not running, TIMESYNC is unable to resolve and the server abends.

A workaround would be to configure timesync with IP Address, instead of Name.

For additional information on NetWare 6, please see the following solution.  TID #10064501 - NetWare 6 Readme Addendum

document

Document Title: Abend: page fault processor execption in timesync.nlm
Document ID: 10067055
Solution ID: NOVL67006
Creation Date: 21Dec2001
Modified Date: 30Oct2002
Novell Product Class:NetWare

disclaimer

The Origin of this information may be internal or external to Novell. Novell makes all reasonable efforts to verify this information. However, the information provided in this document is for your information only. Novell makes no explicit or implied claims to the validity of this information.
Any trademarks referenced in this document are the property of their respective owners. Consult your product manuals for complete trademark information.