Server abending in TCPIP.NLM when FTPing to it.
(Last modified: 09Feb2002)
This document (10066152) is provided subject to the disclaimer at the end of this document.
fact
Novell NetWare 6.0
Server Abends
symptom
Server abending in TCPIP.NLM when FTPing to it.
NIC has both IP and IPX bound at full duplex.
cause
Duplex mismatch issue.
fix
Switching the NIC to half duplex fixed the Abend in this case.
tFor additional information on NetWare 6, please see the following solution. TID #10064501 - NetWare 6 Readme Addendum
document
Document Title: | Server abending in TCPIP.NLM when FTPing to it. |
Document ID: | 10066152 |
Solution ID: | NOVL63984 |
Creation Date: | 16Nov2001 |
Modified Date: | 09Feb2002 |
Novell Product Class: | NetWare |
disclaimer
The Origin of this information may be internal or external to Novell. Novell makes all reasonable efforts to verify this information. However, the information provided in this document is for your information only. Novell makes no explicit or implied claims to the validity of this information.