Slow preformance opening explorer or UNC locations or accessing MS servers.
(Last modified: 29Jan2004)
This document (10090785) is provided subject to the disclaimer at the end of this document.
fact
UNC path filter is enabled on the client advanced settings.
Novell Client 4.9 For Windows NT/2000/XP
symptom
Slow preformance opening explorer or UNC locations or accessing MS servers.
First access is slow then later access is faster.
Traces show workstation trying to access MS devices over Port 524 which is the Novell server port.
cause
Client has been able to resolve the names over one of the resolution methods.
fix
Create the following multi string value key on the workstation with Regedt32
document
Document Title: | Slow preformance opening explorer or UNC locations or accessing MS servers. |
Document ID: | 10090785 |
Solution ID: | NOVL95230 |
Creation Date: | 29Jan2004 |
Modified Date: | 29Jan2004 |
Novell Product Class: | NetWare |
disclaimer
The Origin of this information may be internal or external to Novell. Novell makes all reasonable efforts to verify this information. However, the information provided in this document is for your information only. Novell makes no explicit or implied claims to the validity of this information.
Any trademarks referenced in this document are the property of their respective owners. Consult your product manuals for complete trademark information.