novell-nwcore-1.0.4-1 for SLES10sp1 and SLES10sp2
This document (5038980) is provided subject to the disclaimer at the end of this document.
patches this patch supersedes
| File | Product | Status | Patch |
|---|---|---|---|
| novpatch8860.zip | NetWare 6.5 SP7 | Obsolete | nwcoredumpd modules to facilitate coredumps on virtulized NetWare |
patches that supersede this patch
patch attributes
document
abstract
novell-nwcore-1.0.4-1 nwcoredumpd modules to facilitate coredumps on virtulized NetWare.
details
System Requirements:
OES2 and Virtualized NetWare (NW65sp7)
Installation:
Install the correct rpm for SLES version and architecture as root user.
Note: For SLES 10 SP3 and SLES 11, use the SLES10-SP2 RPM.
rpm -ivh novell-nwcore-1.0.4-1...
Managing the service:
Start ./etc/init.d/novell-nwcore start
Stop ./etc/init.d/novell-nwcore Stop
Status ./etc/init.d/novell-nwcore status
Default location for writing coredump:
/var/log/nwcore
If you wish to change the location of where the coredump is written, modify the /etc.init.d/novell-nwcore file and change the following:
"ARGS="/var/log/nwcore""
-On each instance of Virtualized NetWare, Copy Diag500.nlm to c:\nwserver.
unload diag500.nlm
load diag500.nlm (new version)
-To test the new coredump ability, enter the command "386debug" on server console. This will cause the server to enter the debugger.
-Use the normal commands to navigate the debugger. ".c" will initiate the coredump.
-Answer the prompts as desired.
Reboot the server after coredump (y/n)
Coredump type: 1) Full coredump 2) Full without Cache
Compress coredump? 1) Yes 2) No
Where should diagnostic coredump be sent? 1) XENHOST 2) NETWORK 3) HDISK
Note:Option"1" should be selected to send the coredump to DOM(0).
-The coredump will be written to the system.
Known Problems and Limitations:
Notes: The keyboard may be slow to respond to key strokes while in the debugger. The system may become unresponsive if the
file contents
Compressed File Name: novell-nwcore-1.0.4-1.tar.gz
| Files Included | Size | Date |
|---|---|---|
| novell-nwcore-1.0.4-1/sles10-sp1/novell-nwcore-1.0.4-1.i586.rpm | 13.7 KB (14069) | 2008-12-02 09:57:37 |
| novell-nwcore-1.0.4-1/sles10-sp1/novell-nwcore-1.0.4-1.x86_64.rpm | 14.1 KB (14539) | 2008-12-02 09:57:37 |
| novell-nwcore-1.0.4-1/sles10-sp2/novell-nwcore-1.0.4-1.i586.rpm | 13.7 KB (14060) | 2008-12-02 09:57:40 |
| novell-nwcore-1.0.4-1/sles10-sp2/novell-nwcore-1.0.4-1.x86_64.rpm | 14.1 KB (14531) | 2008-12-02 09:57:40 |
| novell-nwcore-1.0.4-1/diag500/DIAG500.NLM | 173.3 KB (177536) | 2008-12-02 10:57:57 |
| readme_5038980.html | N/A | 2010-04-07 11:22:42 |
disclaimer
The Origin of this information may be internal or external to Novell. Novell makes all reasonable efforts to verify this information. However, the information provided in this document is for your information only. Novell makes no explicit or implied claims to the validity of this information. Any trademarks referenced in this document are the property of their respective owners. Consult your product manuals for complete trademark information.